Objectives
Deals with the design, development and fabrication of Electronic Instruments.
Activities
- R&D Works
- Design & Development of Portable Radiation Dose Rate Meter, Area Radiation Monitor, Hand and Foot Radiation Monitor, Scintillation Survey Meter, PC Based Area Radiation Monitor (Under Crash Program), PC Based Reno graphic System (Under Crash Program) etc.
- Schematic diagram, PCB Design, Etching & Fabrication of Portable Radiation Dose Rate Meter, Area Radiation Monitor, Hand and Foot Radiation Monitor, Scintillation Survey Meter etc.
- Services
- Repair & Maintenances of instruments that are designed & fabricated in this division.
- Electronic calibration of Nuclear Instruments that are designed in this division.
Achievements
- Portable Radiation Dose Rate Meter has been using in different Institutes/Centers/Units of inside and outside of BAEC.
- Area Radiation Monitor has been working in 3M Research Reactor and Gamma Source Division, Institute of Food and Radiation Biology (IFRB), Savar, Dhaka.
- Hand and Foot Radiation Monitor has been working successfully in 3M Research Reactor, Radio Isotope Production Division (RIPD), Institute of Nuclear Science and Technology (INST), Savar, Dhaka.
- Scintillation Survey Meter has been using in Beach Sand Mineral Exploitation Center (BSMEC), Cox’sbazar, Chittagong.
Major Facilities
- Oscilloscope, Power supply, Function Generator, Power Drill Machine, Frequency counter, NIM BIN Counter, PIC Microcontroller Kit etc.
- Broad band Internet connection.
Perspective Plan
Short Term (2007-2010)
- Design and Development of a Portable Radiation Dose Rate Meter
- Design and Development of an Area Radiation Monitor
- Design and Development of a Hand and Foot Radiation Monitor
- Design and Development of a Microcontroller Based Instrument
- Design and Development of a Digital Scintillation Survey Meter
- Design and Development of Microcontroller Based pH Meter
- Fabrication of a Nuclear Electronic Equipment
Mid Term (2007-2015)
- Design and Development of a Microcontroller Based Unbalanced Voltage and Over-load Protection for Three Phase Motor
- Design and Development of a Low Cost Portable Nucleonic Gauge
- Design and Development of a Microcontroller Based Instrument
- Design and Development of an Area Radiation Monitor
- Design and Development of a Portable Radiation Dose Rate Meter
- Fabrication of a Nuclear Electronic Equipment
Long Term (2007-2020)
- Design and Development of an Area Radiation Monitor
- Design and Development of a Low Cost Portable Nucleonic Gauge
- Design and Development of a Universal Solar Home System
- Design and Development of a Microcontroller Based Instrument
- Design and Development of a Portable Radiation Dose Rate Meter
- Design and Development of a Digital Pre-Paid Energy Meter
- Fabrication of a Nuclear Electronic Equipment
Publications
| Title | Name of Author(s) | Name of Journal |
|---|---|---|
| Effect of high Voltage and High Frequency of Living System and Environment. | M.Quamruzzaman, Md. Serajul Islam, Mohammod Abu Sayid Haque, Fahmida Akter andFarhana Hafiz | Journal of the Bangladesh Electronics Society, Vol. 5, No. 1, P=91-96, 2005,ISSN: 1816-1510. |
| Design And Development of Portable Radiation Dose Rate Meter. | Fahmida Akter, Farhana Hafiz, Md. Abu Sayid Haque, Md. Serajul Islam and M. Quamruzzaman. | Journal of the Bangladesh Electronics Society, Vol. 5, No. 2, P=115-120, December 2005, ISSN: 1816-1510 |
| Design and Development of a ±15V, 2A regulated DC power Supply with over-voltage & over-current protection. | Mohammod Abu Sayid Haque, Fahmida Akter and Farhana Hafiz | Institute of Electronics Technical Report, IE-20/GE-11, March 2006. |
| Design and Development of High Voltage Power Supply for Area Radiation Monitor | Fahmida Akter, Farhana Hafiz, Mohammod Abu Sayid Haque, Md. Serajul Islam and Md. Rajibur Rahman Khan | Institute of Electronics Technical Report, IE-21/GE-12, March 2007 |
| Design And development of Microcomputer based Humidity Monitor | Mohammod Abu Sayid Haque, Humayun Kabir, A.S.M.Firoz, Md.Serajul Islam, Prof.Md.Abdul Mannan Chowdhury, Fahmida Akter and Farhana Hafiz | Institute of Electronics Internal Report, IE-22/RM-2, September 2007. |
| Design and Development of a Microcontroller based Area Radiation Monitor | Farhana Hafiz, Fahmida Akter, Mohammod Abu Sayid Haque, MD. Serajul Islam, M A Mannan Chowdhury and Tahmina Rahman | National Conference on Electronics, Information and Telecommunication, 29-30 June, 2007 Rajshahi University, Rajshahi-6205, Bangladesh. Seminer proceedings (ISBN:984-300-000645-7). P-117. |
| Design and Development of a portable scintillation survey meter. | Fahmida Akter, Farhana Hafiz, Mohammod Abu Sayid Haque, MD. Serajul Islam, M A Mannan Chowdhury and tanu Shree Roy | National Conference on Electronics, Information and Telecommunication, 29-30 June,2007Rajshahi University,Rajshahi-6205, Bangladesh.Seminer proceedings (ISBN:984-300-000645-7). P-161. |
Resource Person
| Name & E-mail Address | Designation | Last Qualification | Field of Specialization |
|---|---|---|---|
| Md. Serajul Islam gepdie@bangla.net | CSO | M.Sc. | Instrumentation |
| Ms. Farhana Hafiz gepdie@bangla.net | SSO | B.Sc. Engineering | Instrumentation |
| Ms. Fahmida Akter gepdie@bangla.net | SO | B.Sc. Engineering | Instrumentation |
Other Information
- Participate in Seminar and Lecture Program
- Seminar delivered on
- “Microcontroller based Radiation Monitor”, September 11, 2006, Seminar Hall, Institute of Electronics (IE), AERE, Savar, Dhaka. Speaker: Ms. Fahmida Akter.
- “PC Based Nuclear Radiation Counting System (High Voltage Power Supply)”, March 1 19, 2008, Seminar hall, Institute of Electronics (IE), AERE, Savar, Dhaka.Speaker: Ms. Fahmida Akter.
- “PC Based Nuclear Radiation Counting System (Software)”, March 19, 2008, Seminar hall, Institute of Electronics (IE), AERE, Savar, Dhaka. Speaker: Ms. Farhana Hafiz.
- Lecture delivered on
- “Gamma Camera”, February 17, 2008, Seminar hall, Institute of Electronics (IE), AERE, Savar, Dhaka. Speaker: Md. Serajul Islam.
- Seminar delivered on
- Thesis Supervision
A number of students of different Universities completed thesis work for partial fulfillment of the degree of Master of Science.
Title of Thesis Supervised by Name of Department and University Design and Development of a pc based gauge for measuring thickness using nuclear technique Md. Serajul Islam Department of Physics, Jahangirnagar University Design and Development of Beta-Gamma Radiation Floor Monitor Md. Serajul Islam and Fahmida Akter Department of Physics, Jahangirnagar University Design and Development of Radiation Cloth Monitor Md. Serajul Islam and Farhana Hafiz Department of Physics, Jahangirnagar University Design and Development of AREA radiation monitor for 3MW research reactor Md. Serajul Islam Department of Electronics& Applied Physics, Islamic University, Kushtia Design and Development of Portable Scintillation survey Meter Mohammod Abu Sayid Haque and Fahmida Akter Department of Physics, Jahangirnagar University Design and Development of Microcontroller Based Digital Area Radiation Monitoring System Mohammod Abu Sayid Haque and Farhana Hafiz Department of Physics, Jahangirnagar University Design and Development of Microcontroller Based Furnace Controller Mohammod Abu Sayid Haque and Farhana Hafiz Department of Physics, Jahangirnagar University Design and Development of Microcontroller Based position Controller Mohammod Abu Sayid Haque and Fahmida Akter Department of Physics, Jahangirnagar University Design and Development Microcomputer based Humidity Monitor A S M Firoz and Mohammod Abu Sayid Haque Department of Physics, Jahangirnagar University Design and Development of Microcontroller based Digital pH Meter Mohammod Abu Sayid Haque and Farhana Hafiz Department of Physics, Jahangirnagar University Design and Development of Auto Reset Time Delay Under Voltage, Over Voltage and Over Load Current Protector Md. Serajul Islam and Farhana Hafiz Department of Physics, Jahangirnagar University Design and Development of Microcontroller based Portable Scintillation Radiation Survey Meter Mohammod Abu Sayid Haque and Fahmida Akter Department of Physics, Jahangirnagar University
- Industrial Attachment Training (IAT)
Industrial Attachment Training program was conducted for the students of different universities and polytechnique institutes.
Specifications of Following Instruments are given bellows that are designed by General Electronics Division:
PORTABLE RADIATION DOSE RATE METER
Specifications Casing Size: 250 X 95 X 130mm including handle
Weight: 1.3 Kg
Material: PlasticDetection Beta & Gamma Dose rate range 0-10 µSv/h, 0-100 µSv/h and 0-1000 µSv/h. Battery type Can style "C", 1.5 volt (4 batteries) Battery life 80 hours normal operation High Voltage 575Vdc Indication Signal, Low Battery Scaling Linear, 0 to 10 µSv/h Ambient temperature 10 to 50 degree Celsius Relative humidity Up to 90% non-condensing Detector type End window type G-M tube Window thickness 1.5 to 2.0 mg/cm2 Window diameter 28mm
SCINTILLATION SURVEY METER
Specifications Power supply 9 volt PP-3 battery. Detector Type Scintillation detector PGS-3 of Technical Associates, U.S.A Crystal material NaI(TI) Crystal diameter 1.00" Crystal thickness 1.00" Detection Gamma High voltage 1050 volts d.c. Measurement ranges 0-200 c.p.s for ×1 range. 0 -2k c.p.s for ×10 range. 0-20k c.p.s for ×100 range. Display Linear rate meter (0-100) Indication Signal: Green LED
Low battery: Yellow LED
High radiation: Red LEDAlarm Audible buzzers for signal indication
AREA RADIATION MONITOR
Specifications Casing Size: 290X198 X 130mm
Weight: 2.5 Kg
Material: Plastic/ MetalMains supply 220 volt, 50Hz High Voltage 575Vdc Dose rate range 0-100 µSv/h , 0-1,000 µSv/h and 0-10mSv/h Detection Gamma Protection Input and output fuse protection Indication Low level, High level, High High level, Over voltage indicator & Main supply Scaling Linear, 0 to 100 µSv/h Ambient temperature 10 to 50 degree Celsius Relative humidity Up to 90% non-condensing Detector Type Energy compensated GM Detector, Range 40Kev to 1.25 MeV (Cs137) Detector sensitive length 27mm Alarm Buzzer is intermounted.
HAND AND FOOT RADIATION MONITOR
Specifications Mains voltage 220 volts, 50Hz Detector Type GM pancake type (window diameter 2 inch) Detection Beta, Gamma High voltage 950 volts dc Measurement ranges 0-100µSv/h Control system Full automatic electronic circuit control system by IC Display Analog panel meter Status indicator Green light for clean and red light for dirty Alarm setting range Alarm can be set at any point within the full scale deflection Scaling Linear, 0 to 100 µSv/h Alarm display Display lamps and buzzer sound